->

BETA CAE Systems v14.1.1 Win64-SSQ
BETA CAE Systems v14.1.1 Win64-SSQ | 1.19GB

BETA CAE System S.A. announces the release of v14.1.1 of our ANSA & μETA pre- and –post processing suite with additional new features and tools, and enhancements in the existing ones.


New features, Enhancements and Known Issues Resolved in ANSA
    The translation Option window now automatically pops-up when importing a native file (CATIA, ProE, etc.) directly into ANSA. It is also possible to enable or disable the automatic pop-up
    A new function that verifies whether the ANSA connection entities and the geometrical representations of these connections match
    When projecting a closed single perimeter or edges, the option to open a hole is now available
    The PATRAN calculation method for the solid elements skewness criterion has been implemented
and more...

Known Issues Resolved in ANSA
    The option to “Generate tubes center line” could lead to unexpected termination
    Removing stored bookmarks in On-Line Help Window would lead to unexpected termination
    Occasionally, curves and the points could not be read from VDA files
    The values for Margin and Spacing would not be kept in the Multiple connection points window
    The ADHESIVE tool would create 1 layer regardless of the input in the “number of layers” field
    The BOLT_ON_SOLID representation would fail to realize whether the option “Last Tube Body Type” was “same”
    The SOLID_NUGGET representation would not respect the option “Dist from perimeter”
    The option “Split remaining violating quads” in Fix Qual tab, would lead to unexpected termination
    When using ALIGN, the latest selected direction points or plane would be kept for the new selection of intended for alignment nodes
    When a closed single perimeter (or edges) was projected, the resulting mesh would also have an opened hole
    When modifying beam properties through the lists (e.g. Database browser), the blank fields would be filled with a random value
    The Reposition Flanges Fix option would not move the flanges on the desired distance
    NOM2REAL morphing function could lead to unexpected termination on Windows OS
    Solid attached on geometry would make the DFM morphing function to fail
    Blank values of ND in EIGRL card are now supported
    Editing the Damping Patch task item would lead to unexpected termination (Nastran)
    The value in D4 field for SECTION_BEAM_ELFORM_2 would not be outputted (LS-DYNA)
    Saving the MatDB would save Curves and Tables that were not used by any material (LS- DYNA)
    When negative RSYS ids existed, the mass was not read-in (MEDINA)
    The option to create new property (BEAM>New) was missing (PERMAS)
    .tdf files would not be read-in at Windows OS (RadTherm)
    Beam elements created through Elements>Util>Reinforcement to Beam (Nastran), would not be exported (SESTRA)


New features, Enhancements and Known Issues Resolved in µETA
    Support of Abaqus CPRESS SPOS contact pressure results on shell elements
    The FMVSS_201U toolbar can now map the HIC values on the model for Results Overview
    The CFD Post toolbar can now process binary STAR-CCM+ and SC/TETRA result files
and more...

Known Issues Resolved in µETA
    Results could not be read from certain Abaqus .odb files
    In certain cases density information was not properly read from Nastran SOL200 *.des files
    Curves could not be created from certain Pamcrash .THP files
    Reading certain Permas *.uci files could lead to unexpected termination
    Reading large SC/TETRA *.fld files could lead to unexpected termination
    Saving Statistics data in .csv format could lead to unexpected termination
    Plotting Panel Participation results in the Modal Response tool could lead to unexpected termination
    Saving .pptx reports after copying or deleting slides could lead to unexpected termination
    The creation of Parametric Point paths by picking nodes was not correct
    Images were not saved correctly in batch mode in certain cases
    The MetaDB Translator would not save vector results correctly
and more...

Compatibility
ANSA files saved with version 14.1.1 can be opened by v14.0.x but not previous versions.
The .metadb files saved with μETA version 14.1.1 are compatible and can be opened by earlier versions of μETA



 TO MAC USERS: If RAR password doesn't work, use this archive program: 

RAR Expander 0.8.5 Beta 4  and extract password protected files without error.


 TO WIN USERS: If RAR password doesn't work, use this archive program: 

Latest Winrar  and extract password protected files without error.


 GonBi   |  

Information
Members of Guests cannot leave comments.




rss